SPS 131.32(7)(a)4.4. Amperage and voltage ratings of the service, including whether service type is overhead or underground. SPS 131.32(7)(a)5.5. Branch circuit conductors, their over current devices, and the compatibility of their ampacities and voltages, including any aluminum branch circuit wiring. SPS 131.32(7)(a)6.6. The operation of a representative number of installed lighting fixtures, switches and receptacles located inside the house, garage and any exterior walls. SPS 131.32(7)(a)7.7. The polarity and grounding of all receptacles within 6 feet of interior plumbing fixtures, in the garage or carport, and on the exterior of inspected structures. SPS 131.32(7)(b)(b) A home inspector is not required to do any of the following: SPS 131.32(7)(b)2.2. Test or operate any over current device except ground fault circuit interrupters. SPS 131.32(7)(b)3.3. Dismantle any electrical device or control other than to remove the covers of the main and auxiliary distribution panels. SPS 131.32(7)(b)4.4. Observe low voltage systems, telephones, security systems, cable TV, intercoms, or other ancillary wiring that is not a part of the primary electrical distribution systems. SPS 131.32(8)(a)(a) A home inspector shall observe and describe the condition of all of the following: SPS 131.32(8)(a)5.5. Separation walls, ceilings, and doors between a dwelling unit and an attached garage or another dwelling unit. SPS 131.32(8)(a)6.6. Signs of water penetration into the building or signs of abnormal or harmful condensation on building components. SPS 131.32(8)(b)(b) A home inspector is not required to observe any of the following: SPS 131.32(8)(b)1.1. Paint, wallpaper, and other cosmetic finish treatments on the interior walls, ceilings and floors. SPS 131.32(9)(a)(a) A home inspector shall observe and describe the condition of all of the following within a permanently installed heating system: SPS 131.32(9)(b)(b) A home inspector shall operate the systems using normal operating controls and open readily accessible access panels provided by the manufacturer or installer for routine homeowner maintenance. SPS 131.32(9)(c)(c) A home inspector is not required to do any of the following: SPS 131.32(9)(c)1.1. Operate heating systems when weather conditions or other circumstances may cause equipment damage. SPS 131.32(9)(c)4.4. Observe the interior of flues, fireplace insert flue connectors, humidifiers, electronic air filters, or the uniformity or adequacy of heat supply to the various rooms. SPS 131.32(9)(c)5.5. Observe a heat exchanger unless it is readily observable and normally accessible to an occupant of a dwelling unit. SPS 131.32(10)(a)(a) A home inspector shall observe and describe the condition of all of the following: SPS 131.32(10)(b)(b) A home inspector shall operate the systems, using normal operating controls, and open readily accessible access panels provided by the manufacturer or installer for routine homeowner maintenance. SPS 131.32(10)(c)1.1. Operate cooling systems when weather conditions or other circumstances may cause equipment damage. SPS 131.32(10)(c)3.3. Observe the uniformity or adequacy of cool-air supply to the various rooms. SPS 131.32(10)(c)5.5. Observe the pressure of the system coolant or determine the presence of leakage. SPS 131.32(11)(a)(a) A home inspector shall observe and describe the condition of all of the following: SPS 131.32(11)(b)(b) A home inspector is not required to observe any of the following: SPS 131.32 HistoryHistory: Cr. Register, July, 1999, No. 523, eff. 8-1-99; CR 14-010: renum. 131.32 from SPS 134.03 Register August 2014 No. 704, eff. 9-1-14. SPS 131.33SPS 131.33 Contents of a home inspection report. SPS 131.33(1)(1) After completing a home inspection, a home inspector shall submit a written report to a client that does all of the following: SPS 131.33(1)(bm)(bm) States the property address, the name of the home inspector who conducted the home inspection, the date of the home inspection, the names of the individuals who prepared the report, the date the report was prepared, and, if applicable, the date the report was revised. SPS 131.33(1)(d)(d) Describes any defect that is detected by the home inspector during his or her home inspection. A home inspector shall use the term “defect” in describing a condition in the written report required under this subsection if the home inspector believes the condition satisfies the definition of “defect” under s. 440.97 (2m), Stats. SPS 131.33(1)(e)(e) Lists any material adverse facts that a home inspector has knowledge of or has observed. SPS 131.33(1)(f)1.1. A list of conditions, labeled as defects, that are observed under par. (d) to be defects. SPS 131.33(1)(f)2.2. Other than items labeled as defects, a listing of components needing repairs, components needing further evaluation, items to monitor, and maintenance items. SPS 131.33(1)(f)3.3. References to the page, heading, or item number in the full written report for further information. SPS 131.33(2)(2) A home inspector is not required to report on any of the following aspects of items identified in s. SPS 131.32: SPS 131.33(2)(c)(c) The method of making any repair or correction, the materials needed for any repair or correction, or the cost of any repair or correction. SPS 131.33(2)(d)(d) The suitability for any specialized use of an improvement to residential real property. SPS 131.33(2)(e)(e) Whether they comply with applicable regulatory requirements. SPS 131.33(4)(4) A home inspector is not required to retain inspectors or investigators to perform follow-up inspections or investigations of any material adverse facts that a home inspector has knowledge of or has observed under sub. (1) (d). SPS 131.33 HistoryHistory: Cr. Register, July, 1999, No. 523, eff. 8-1-99; correction in (1) (a), (b), (c), (d), (2) (intro.) made under s. 13.92 (4) (b) 7., Stats., Register November 2011 No. 671; CR 14-010: renum. 131.33 from SPS 134.04 and am. (1) (a), (b) Register August 2014 No. 704, eff. 9-1-14; corrections in (1) (c), (d), (2) (intro.) made under s. 13.92 (4) (b) 7., Stats., Register August 2014 No. 704; EmR1822: emerg. am. (1) (d), cr. (2m), (3m) eff. 9-23-18; CR 18-076: am. (1) (d), cr. (2m), (3m) Register May 2019 No. 761, eff. 6-1-19; EmR2202: emerg. cr. (1) (bm), r. and recr. (1) (d), cr. (1) (f), r. (2m), (3m), eff. 1-15-22; CR 22-004: cr. (1) (bm), r. and recr. (1) (d), cr. (1) (f), r. (2m), (3m) Register June 2023 No. 810, eff. 7-1-23; correction in (1) (f) made under s. 13.92 (4) (b) 4., Stats., Register June 2023 No. 810. SPS 131.40SPS 131.40 Education requirement for initial registration. An applicant for registration as a home inspector must have completed at least 40 hours of pre-registration instruction approved by the department under s. SPS 131.405. SPS 131.40 HistoryHistory: EmR2202: emerg. cr., eff. 1-15-22: CR 22-004: cr. Register June 2023 No. 810, eff. 7-1-23.
/code/admin_code/sps/professional_services/131/131
true
administrativecode
/code/admin_code/sps/professional_services/131/131/iv/32/9/a
Department of Safety and Professional Services (SPS)
Chs. SPS 1-299; Professional Services
administrativecode/SPS 131.32(9)(a)
administrativecode/SPS 131.32(9)(a)
section
true